Sealed Box Airflow Suction Test
How we do it
This test measures what a vacuum does at the cleaner head, the part that touches your floor. Motor ratings and brochure numbers tell you what happens inside the machine. The sealed box tells you what's left by the time the air reaches your carpet, after the filters and every leaky seal have taken their cut.The cleaner head sits on a box that seals around its edges, so the only way air gets in is through one opening of a known size. An anemometer in that opening reads air speed, and air speed times the size of the opening gives airflow in cubic feet per minute (CFM). Block the opening and a gauge reads suction, in inches of water lift.Some heads are built to leak on purpose, with vents for soft carpet or bleeder valves that open in certain modes. When a head won't seal, it gets taped or run in the mode that seals, and the reading says so. If a head still wouldn't seal, that goes on the reading too, because it affects the numbers.Airflow is how much air is moving to carry dirt into the machine. Suction is how hard it pulls when the air is choked off. Plenty of machines are strong in one and weak in the other, so we show both. Readings from the same box compare cleanly. Other testers' boxes differ a little, which is why every reading names who took it.
Equipment
The core apparatus is a sealed plywood airflow box built from 3/4 inch stock at 18 by 18 inches, glued and screwed tightly enough to hold an air and watertight seal under load. It uses a reversible dual-chamber design, with one large sealed compartment sized for full-size American vacuums and a separate smaller compartment for European and compact machines, selected simply by flipping the box over. Each face carries a measurement hole where the vacuum nozzle seals against the box and where an airflow meter reads velocity through the opening.